(5 points)
Exterior Light Pollution: Path A or B (5 points)
GREEN GLOBES #2.6.1 - ANSI #7.6
There are two paths available for assessing exterior light pollution:
- (#2.6.1.1) Path A: Lighting Design Performance: 5 points
OR
- (#2.6.1.2) Path B: Prescriptive Lighting Requirements: 5 points
Points cannot be combined between paths. Select one of the paths.
PATH A.
GREEN GLOBES #2.6.1.1 - ANSI #7.6.1.1 Has an engineer or lighting professional created a lighting design that meets all the performance requirements of the IDA - IES Model Lighting Ordinance?
- Yes (5 points)
- No (0 points)
- N/A
Assessment Guidance
Not applicable where there is no site lighting.
References
- IDA – IES Model Lighting Ordinance (MLO, 2011)
Recommended Documents
- Electrical engineer’s site lighting plan with illuminance computations spaced no more than 10 ft. (3.05 m) apart
PATH B.
GREEN GLOBES #2.6.1.2.1 - ANSI #7.6.2.1 Does exterior lighting avoid exceeding prescribed values for the amount of light per unit of the area?
- Yes (1 point)
- No (0 points)
- N/A
Assessment Guidance
Not applicable where there is no exterior lighting.
References
- IDA – IES Model Lighting Ordinance (MLO), Tables A and B, 2011
Recommended Documents
- Exterior lighting plans
- Cut-sheets and calculations
GREEN GLOBES #2.6.1.2.2 - ANSI #7.6.2.2 Does exterior lighting trespass avoid exceeding prescribed Backlight, Uplight and Glare (BUG) ratings?
- Yes (3 points)
- No (0 points)
- N/A
Assessment Guidance
Prescribed ratings are per IDA – IES Model Lighting Ordinance (MLO), Table C for the following:
- Backlight trespass;
- Uplight trespass; and
- Glare
Not applicable where there is no exterior lighting.
References
- IDA – IES Model Lighting Ordinance (MLO), Tables C, C1, C2, 2011
Recommended Documents
- Path taken for compliance to the MLO
- Exterior lighting plans
GREEN GLOBES #2.6.1.2.3 - ANSI #7.6.2.3 Does parking lot lighting avoid emitting light above 90 degrees from the vertical axis?
- Yes (1 points)
- No (0 points)
- N/A
Assessment Guidance
Not applicable where there is no parking lot lighting.
Recommended Documents
- Zoning ordinance requirements
- Narrative describing which lighting zone the property falls under
- Exterior lighting plans
© 2020 Green Building Initiative, Inc. ALL RIGHTS RESERVED.