(1-30 points)
Intent
To improve the home’s overall energy performance and reduce its greenhouse gas emissions.
Requirements
Follow the criteria in EA Prerequisite Minimum Energy Performance to demonstrate a percentage improvement in the proposed building’s performance compared with the baseline building performance of ASHRAE 90.1–2010, or USGBC-approved equivalent standard for projects outside the U.S. Points are awarded according to Table 5.
Table 5. Points for reducing energy usage below ASHRAE baseline
Percentage reduction | Points |
---|---|
6% | 1 |
7% | 2 |
8% | 3 |
9% | 4 |
10% | 5 |
11% | 6 |
12% | 7 |
13% | 8 |
14% | 9 |
15% | 10 |
16% | 11 |
17% | 12 |
18% | 13 |
19% | 14 |
20% | 15 |
22% | 16 |
24% | 17 |
26% | 18 |
28% | 19 |
30% | 20 |
33% | 21 |
36% | 22 |
39% | 23 |
42% | 24 |
45% | 25 |
48% | 26 |
51% | 27 |
54% | 28 |
57% | 29 |
60% | 30 |
AND
Earn 1 point for every 4% decrease in conditioned floor area compared with the ENERGY STAR for Homes, version 3, reference home (Table 1). Buildings that are larger than the reference home lose 1 point for every 4% increase in conditioned floor area.
Projects cannot exceed the maximum number of points in the EA section.
Table 6. Conditioned floor area of reference home, by number of bedrooms
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 or more | |
Floor area (square feet) | 1,000 | 1,600 | 2,200 | 2,800 | 3,400 | 4,000 | 4,600 | + 600 ft2 per additional bedroom |
Floor area (square meters) | 93 | 148 | 204 | 260 | 315 | 371 | 426 | + 55.6 square meters per additional bedroom |
For multifamily buildings, home size includes only in-unit space.